We help our customers to develop their own nucleic acid detection system with minimum cost and shortest cycle time.
High integration:
a single-bay PCR module covering temperature control system, optical system and circuit control system, which can be operated by powering up.
Automatic lid opening:
adopting electromagnetic lock technology, which can access the automatic lid opening function.
Flexible combination:
support 6 groups of modules working simultaneously or independently;
Efficient and fast:
the fastest 20min to complete a round of testing, can realize the flow of testing mode;
Application Development
1. Develop customized nucleic acid detection equipment with different appearance requirements.
2. Integrated in various portable devices to realize portable field testing special equipment.
3. Integrated in the table-top all-in-one machine to realize fully automatic nucleic acid testing platform.
4. Integrated in nucleic acid testing kiosk, with fully automatic robot, to achieve fully automatic nucleic acid sampling and testing kiosk.
More applications are waiting for you to develop together...
Main Technical Parameters
Basic Parameters | |
Specification Model | MQ0 module |
# of wells | 4 wells, 8 wells, 16 wells available |
# of Channels | 4(1.FAM/SYBR Green;2.JOE/HEX/VIC/TET;3.ROX;4.CY5) |
Applicable Consumables | 0.2ml eight-link tube or 0.2ml single tube |
Multiplexing | Up to 4-plex fluorescence detection without channel cross-interference correction |
Reaction System | 10-60uL |
Sensitivity* | Single copy gene detectable |
Operating System | External Android connection available |
Size and Weight | 300*218*85mm, about 2kg |
Temperature Control System Parameters | |
Temp Control Technology | Adopt the high-level semiconductor chip of MARLOW company, the cycle times can reach one million times. The unique temperature control software algorithm coordinates and manages the semiconductor heating, auxiliary heating and cooling systems, which not only ensures the accuracy of temperature control, but also increases the rate of heating and cooling, and accurately controls the temperature. |
Heating Rate* | 8.0℃/s(MAX) |
Cooling Rate* | 5.5℃/s(MAX) |
Temp Uniformity* | <0.5℃ |
Temp Accuracy* | ±0.5℃ |
Optical System Parameters | |
Optical Core Technology | Multi-channel fixed light splitting and filtering imaging system. long-term use does not require expensive and cumbersome periodic calibration maintenance, and high reliability. One chip per channel, no moving scanner, maintenance free. |
Excitation Light Source | Long life maintenance-free LED. The free-form surface concentrating system has the excitation light intensity increased by 200%, and no calibration is required, cost effective. |
Excitation Wavelength | 460nm-670nm |
Emission Wavelength | 510nm-720nm |
Detector | Ultra-low-light CMOS Bio-imaging chip |
Fluorescent Dyes | Channel 1: FAM/SYBR Green I; Channel 2: HEX, VIC, JOE, TET; Channel 3: ROX; Channel 4: CY5; |
* Ideal values measured in a standard laboratory environment.